Training Escalator (two sides) is suitable for patients to perform functional recovery exercises going up and down stairs.
- Item No.:
YB-104-1
- Series:
Gait Training Series
- Usage:
Suitable for patients to perform functional recovery exercises for patients going up and down stairs.
- Remark:
The armrests are height-adjustable.
Construction
1. Armrest
2. Handrail Height Adjustment Bolt
3. Fixed Pipe String
4. Ladder
Data sheet
Size:
337×83×120~147cm
Handrail Adjustment Range:
0-25cm
Step Height:
10cm, 11cm, 12cm, Depth 28cm
Material:
✳Stainless Steel Pipe Handrails
✳Density Board
✳ Carpet
✳Electrostatic Spray Frame
Load:
✳Rated load of handrail side: 70kg
✳Rated load of ladder (kg): 135kg
✳Rated load of ladder (kg): 135kg
Instructions For Use
✳The height of the handrail can be adjusted according to the height of the trainee.
✳The trainee can hold the handrail and do walking exercises up and down the stairs.
Other Information
1. Performance of escalator
✳ Adjustable height of escalator handrail 0-200mm
✳ The load of escalator is in normal use in accordance with the corresponding provisions in Table 1.
✳ After the escalator is placed on the flat ground, the height of the landing point can be adjusted to make the escalator stable.
2. Installation and debugging of escalator
✳ The product is easy to install and can be installed according to the finished product drawing.
✳ Before unpacking the escalator, please check whether the packaging box is intact and check whether the items are complete according to the packing list.
✳ The escalator should be placed on a horizontal ground with corresponding activity space.
✳ Check and adjust the adjustable bolts of the base. Those that are not on the ground should be adjusted to the ground force.
3. Precautions
✳ Before using the escalator, you should read the product manual in detail, familiarize yourself with the performance, requirements and operation methods of the product, and perform no-load operation inspection on the product. It can be used only after it is corrected and in normal state.
✳ During training, you must practice in an orderly manner with the help of rehabilitation therapists and nursing staff. Follow the principle of “gradual progress” and gradually increase the intensity and time of exercise according to the specific situation of the trainee.
✳To avoid accidents, the trainee or others are strictly prohibited from sitting on the handrail of the escalator.
4. Maintenance and care of escalators
✳All parts of the escalator should be kept clean, and the handrail should be wiped with a clean soft cloth regularly to clean the step surface.
✳If the handrail shakes, it should be tightened with tools in time.
✳If the product fails, please contact the manufacturer in time for repair.
5. Packaging, transportation and storage
✳The product is packed in wooden boxes with moisture-proof linoleum inside.
✳The product can be transported by ordinary means of transportation. It should be handled and placed gently during transportation. It should not be subjected to heavy pressure or collision. It should be protected from sun and rain. It is forbidden to mix with pollutants.
✳The product should be stored in a dry, ventilated room without corrosive substances. It should not be subjected to heavy pressure or collision.
✳ Adjustable height of escalator handrail 0-200mm
✳ The load of escalator is in normal use in accordance with the corresponding provisions in Table 1.
✳ After the escalator is placed on the flat ground, the height of the landing point can be adjusted to make the escalator stable.
2. Installation and debugging of escalator
✳ The product is easy to install and can be installed according to the finished product drawing.
✳ Before unpacking the escalator, please check whether the packaging box is intact and check whether the items are complete according to the packing list.
✳ The escalator should be placed on a horizontal ground with corresponding activity space.
✳ Check and adjust the adjustable bolts of the base. Those that are not on the ground should be adjusted to the ground force.
3. Precautions
✳ Before using the escalator, you should read the product manual in detail, familiarize yourself with the performance, requirements and operation methods of the product, and perform no-load operation inspection on the product. It can be used only after it is corrected and in normal state.
✳ During training, you must practice in an orderly manner with the help of rehabilitation therapists and nursing staff. Follow the principle of “gradual progress” and gradually increase the intensity and time of exercise according to the specific situation of the trainee.
✳To avoid accidents, the trainee or others are strictly prohibited from sitting on the handrail of the escalator.
4. Maintenance and care of escalators
✳All parts of the escalator should be kept clean, and the handrail should be wiped with a clean soft cloth regularly to clean the step surface.
✳If the handrail shakes, it should be tightened with tools in time.
✳If the product fails, please contact the manufacturer in time for repair.
5. Packaging, transportation and storage
✳The product is packed in wooden boxes with moisture-proof linoleum inside.
✳The product can be transported by ordinary means of transportation. It should be handled and placed gently during transportation. It should not be subjected to heavy pressure or collision. It should be protected from sun and rain. It is forbidden to mix with pollutants.
✳The product should be stored in a dry, ventilated room without corrosive substances. It should not be subjected to heavy pressure or collision.